Details

Status of RADI - a RF source size-scaling experiment towards the ITER source


P. Franzen, H. Falter, B. Heinemann, Ch. Martens, U. Fantz, M. Berger, S. Christ, A. Encheva, M. Fröschle, D. Holtum, W. Kraus, P. McNeely, R. Riedl, R. Süss, S. Obermayer, E. Speth, A. Tanga, D. Wünderlich


Max-Planck-Institut für Plasmaphysik, EURATOM Association, Postfach
1533, D-85740 Garching, Germany


Abstract: IPP Garching is currently developing a RF source for the ITER neutral beam system. The principle suitability concerning current density (> 20 mA/cm2 D), pressure (0.3 Pa) and electron content (je/jD− ~ 1) has been demonstrated with the test facility BATMAN, but with only small extraction area (~ 70 cm2) and limited pulse length (< 6 s). The further development concentrates now on long pulse operation (at the test facility MANITU, operational this spring) and source size extension.

Synopsis (pdf) Full Paper (pdf) Slides (pdf)