High-Power and Long-Pulse Injection with Negative-Ion-Based Neutral Beam Injectors in Large Helical Device

Y. Takeiri, O. Kaneko, K. Tsumori, Y. Oka, K. Ikeda, M. Osakabe, K. Nagaoka,
E. Asano, T. Kondo, M. Sato, M. Shibuya


National Institute for Fusion Science, Toki 509-5292, Japan

Abstract: A negative-ion-based neutral beam injection (NBI) system has been operated reliably in the Large Helical Device (LHD) since it was operational in 1998. The injection power achieved is 13.1 MW with three injectors. In one injector with modified ion sources with the multi-slotted grounded grid, the injection power reached 5.7 MW with an energy of 184 keV, both of which exceed the designed values of 180 keV - 5 MW. The individual control of the arc-discharge with the divided arc and filament power supplies is effective to improve the beam uniformity. The injection duration is extended to 120 sec with a reduced power of 0.2 - 0.3 MW using one ion source with the cooled plasma grid. The performance of the negative-NBI in LHD is reviewed with regard to the progress of the negative ion sources.