Full Paper
IAEA-CN77
Contents  Return  Previous Page  Next Page  Index


Return To: Session SEP - Safety & Environment
Prev Page: (SEP/01) Study of Decay Heat Removal and Structural
Next Page: (SEP/03) Studies on Nuclear Fusion Energy Potential Based


(SEP/02) Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of-Coolant Events

K. Takase1), H. Akimoto1)
 
1) Japan Atomic Energy Research Institute

Abstract.  An integrated ICE (Ingress-of-Coolant Event) test facility was constructed to demonstrate that the ITER safety design approach and design parameters for the ICE events are adequate. Major objectives of the integrated ICE test facility are: to estimate the performance of an integrated pressure suppression system; to obtain the validation data for safety analysis codes; and to clarify the effects of two-phase pressure drop at a divertor and the direct-contact condensation in a suppression tank. A scaling factor between the test facility and ITER-FEAT is around 1/1600. The integrated ICE test facility simulates the ITER pressure suppression system and mainly consists of a plasma chamber, vacuum vessel, simulated divertor, relief pipe and suppression tank. From the experimental results it was found quantitatively that the ITER pressure suppression system is very effective to reduce the pressurization due to the ICE event. Furthermore, it was confirmed that the analytical results of the TRAC-PF1 code can simulate the experimental results with high accuracy.

Read the full paper in PDF format.

IAEA 2001