International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators

4-8 May 2009, Vienna

ADS/P4-07

Application of ITEP TWAC Accelerator Beams for Diagnostics of Fast Process

A.A. Golubev, V.S. Demidov, A.V. Kantsyrev, G.N. Smirnov, V.S. Skachkov, V.I. Turtikov, and B.Y. Sharkov

Institute for Theoretical and Experimental Physics (ITEP), Moscow, Russian Federation

Corresponding Author: Alexander.Golubev@itep.ru

Parameters of the proton radiographic facility which constructed on the ITEP TWAC accelerator for diagnostic static objects and fast process are reported. Time structure of ITEP TWAC accelerator beam is able to make a diagnostic of dynamic process with characteristic speed up to 20 km/s.

In paper shown that the facility spatial resolution on the sharp edge of the dense object with step up to 4.5 g/cm2 will be 8 μm with contrast factor ~0.67.